ETF 012 Electronic Hygrothermostat

ETF 012 Electronic Hygrothermostat
Product Detailed
Electronic Hygrothermostat ETF 012 Temperature and humidity adjustable LED display High switching capacity Clip fixing

ETF 012 Electronic Hygrothermostat

1.Features:

Temperature and humidity adjustableOptical operating display LED

High switching capacityClip fixing 

The electronic hygrotherm senses the ambient temperature and relative humidity in an enclosure with electric/electronic components, and turns on a heater (or alternatively, a fan) at either set point, helping prevent the formation of condensation in the enclosure. The LED integrated in the adjustment knob on the active controller is lit when the connected device is in operation.

2.Technical Data

Switch difference (temperature)2K (± 1K tolerance) at 25°C/77°F (50% RH)
Switch difference (humidity)4% RH (± 1% tolerance) at 25°C/77°F (50% RH)
Reaction time (humidity)5 sec.
Contact typechange-over contact (relay)
Service lifeNC: 50,000 cycles
 NO: 100,000 cycles
Max. Switching capacity (Relay output)NC: 240VAC, 6 (1) A
 NO: 240VAC, 8 (1.6) A
 NC: 120VAC, 6 (1) A
 NO: 120VAC, 8 (1.6) A
 24VDC, 4A
Optical indicatorLED
Connection5-pole terminal, clamping torque 0.5Nm max.: rigid wire 2.5mm², stranded wire (with wire end ferrule) 1.5mm²
Mountingclip for 35mm DIN rail, EN60715
Casingplastic according to UL94 V-0, light grey
Dimensions77 x 60 x 43mm
Weightapprox. 0.2kg
Fitting positionvertical
Operating/Storage temperature0 to +60°C (+32 to +140°F) / -20 to +80°C (-4 to +176°F)
Operating / Storage humiditymax. 90 % RH (non-condensing)
Protection typeIP20
 

Art. No.Operating voltageSetting range temperatureSetting range humidityApproval
01230.0-00230VAC, 50/60Hz0 to +60°C50 to 90% RHVDE + UL File No. E164102
01230.9-00120VAC, 50/60Hz+32 to +140°F50 to 90% RHUL File No. E164102
01230.9-01120VAC, 50/60Hz0 to +60°C50 to 90% RHUL File No. E164102